Determinazione dell’etanolo con metodo enzimatico su matrici diverse

AUTORI

Luisa Galla1, Lucio Marchioro 1, Mariela Marinova1, Carlo Artusi1, Martina Zaninotto2, Daniela Basso2, Mario Plebani3
1Dipartimento Medicina di Laboratorio, Azienda Ospedale Università Padova
2Università degli Studi di Padova
3QI.LAB.MED.- Spin-off dell’Università di Padova

ABSTRACT

Determination of ethanol using an enzymatic method in different matrices

Introduction: this study was designed to measure ethyl alcohol concentrations in blood samples of different matrices (Li-He plasma, K2-EDTA plasma and serum) with the DRI® method on the ILab Taurus analyzer. The aim of the protocol was to compare the values between the matrices K2-EDTA and serum with Li-He plasma. Furthermore, 18 real samples from the emergency room were used to compare the results obtained with the enzymatic method on both Li-He and K2-EDTA plasma in comparison with the GC/HS reference method.
Methods: serum, Li-He and K2-EDTA samples were obtained from left-over routine samples to obtain different pools (serum, Li-He plasma and K2-EDTA plasma pools). Samples with different expected concentrations of ethanol (range 0.00-2.22 g/L) were prepared in situ (60 samples for each matrix) by precise additions of a 10% ethanol solution. All these samples were stored at -20°C until use.
Results: in the expected concentration range between 0.42 and 0.85 g/L and around 0.8 and 1.5 g/L [which incorporates most of the legally permitted levels of BAC (Blood Alcohol Concentration) in Europe including Italy] the CV% obtained are all <5.0%. The GC/HS correlation with ILab Taurus for both plasma matrices, LI-He and K2-EDTA evaluated in 18 genuine samples was excellent.
Discussion: all the obtained results show that for all the matrices evaluated in the study, the analytical performances are highly satisfactory.

BIBLIOGRAFIA

1. Plebani M, Banfi G, Bernardini S, Bondanini F, Conti L, Dorizzi R, et al. Serum or plasma? An old question looking for new answers. Clin Chem Lab Med 2020;58:178-87.
2. Rapporti ISTISAN 22/1 – Epidemiologia e monitoraggio alcol-correlato in Italia e nelle Regioni, Rapporto 2022. https://www.iss.it/-/rapporti_istisan_22_1 (ultimo accesso: novembre 2023).
3. https://www.epicentro.iss.it/alcol/conferenza-nazionale-alcol-2022 (ultimo accesso: novembre 2023).
4. Penetar DM, McNeil JF, Ryan ET e Lukas SE. Comparison among plasma, and whole blood ethanol concentrations: impact of storage conditions and collection tubes. J Anal Toxicol 2008;32,505-10.
5. Clinical Laboratory Standards Institute (CLSI). Assessment of Equivalence or Suitability of Specimen Types for Medical Laboratory Measurement Procedures, 1stEdition . CLSI document EP35. CLSI Wayne, PA, 2019

 

HOME
PRIVACY POLICY
5x1000 Docemus

LOGO SIBioC

EDITORE RESPONSABILE
Alberto Oliaro

EDITORIAL SECRETARY
Edizioni Minerva Medica S.p.A.
Corso Bramante 83-85, 10126 Torino
T +39 011 678282
journals.dept@minervamedica.it

Designed by Biomedia srl
© 2025 SIBioC
P. IVA IT 06484860967