La fase pre-analitica dei campioni provenienti dal Pronto Soccorso: impatto della introduzione di un impianto di posta pneumatica nel miglioramento del tempo di risposta

AUTORI

Vania Polesello1, Ruggero Dittadi1, Haleh Afshar1, Giulia Bassan1, Mara Rosada2, Luca Del Ninno3, Paolo Carraro1
1Medicina di Laboratorio, Ospedale dell’Angelo, Azienda ULSS 3 Serenissima, Mestre Venezia
2Pronto Soccorso, Ospedale dell’Angelo, Azienda ULSS 3 Serenissima, Mestre Venezia
3Direzione Amministrativa, Ospedale dell’Angelo, Azienda ULSS 3 Serenissima, Mestre Venezia

ABSTRACT

Improving pre-analytical laboratory turnaround time for the emergency department: outcomes of a pneumatic tube system introduction

Background: the pre-analytical phase of the stat tests requested by the Emergency Department (ED) has been rarelystudied in relation to the containment of the laboratory turnaround time (TAT).
Methods: through a pre-analytical workflow analysis in a large ED with “Lean” methodology, some improvementshave been activated, including the installation of a pneumatic tube system (PTS).
Results: significant improvement of TATs (23 minutes at 90th percentile) and also of length of stay (LOS) of EDpatients (53 minutes at 90th percentile) has been documented. The plasma concentrations of a number of analytesmeasured in samples transported manually and by PTS were very similar (lactic dehydrogenase excluded),demonstrating that PTS does not alter the integrity of the samples.
Conclusions: compared to manual transportation, the use of this PTS significantly reduced transport time and alsoimproved some pre-analytical flow phases within the ED. The system is suitable for the measurement of most of theanalytes commonly requested for ED patients