• Passa al contenuto principale
BC

biochimica clinica

it_IT Italian
it_IT Italian en_US English
  • Home
  • Casi clinici
  • Ahead of print e Ultimo Fascicolo - Accedi per visualizzare gli articoli
  • Archivio BC fino a 2024
  • Sottometti un articolo
  • Norme Autori
  • Cerca

CONTRIBUTI SCIENTIFICI – Scientific Papers

Volume:

Biochimica Clinica 2015; 39(4) 256-263

Pubblicato on-line:

DOI:

Scarica in PDF:

Determinazione degli intervalli di riferimento dell’esame emocromocitometrico eseguito con analizzatore Sysmex XN 9000

AUTORI

Sabrina Buoro1, Sara Apassiti Esposito1, Tommaso Mecca1, Giovanna Azzarà1, Lorenzo Cerutti1, Paola Dominoni1,
Alberto Crippa1, Cosimo Ottomano2, Giuseppe Lippi2
1Laboratorio di Analisi Chimico Cliniche, Azienda Ospedaliera Papa Giovanni XXIII, Bergamo
2UO Diagnostica Ematochimica, Azienda Ospedaliero-Universitaria di Parma

ABSTRACT

We aimed to define reference intervals for complete blood count in 240 apparently healthy Italian adults (120 males and 120 females) using Sysmex XN 9000 platform, as recommended by international standards. The recruitment criteria for reference individuals were based on negative anamnesis and physiological serum concentrations of glucose, creatinine, transaminases, ferritin and C-reactive protein. The results were comparable to those previously generated on different European populations. Interesting results were found for some research parameters, for which limited information was available in Italian populations so far. With regard to reticulocyte-related parameters, a significant gender difference was found for reticulocyte hemoglobin, highly fluorescent reticulocyte fraction and delta-He, which represents the difference in hemoglobin content between reticulocytes and erythrocytes. The results also support the reference interval of immature platelet fraction observed in previous studies, except for the absolute value for which larger range and higher values were found. For leukocyte morphological and functional parameters, we were able to define reference intervals in the whole study population as well as in male and female subgroups, since gender-related differences were observed for some parameters.

BIBLIOGRAFIA

HOME
PRIVACY POLICY
5x1000 Docemus

LOGO SIBioC

EDITORE RESPONSABILE
Alberto Oliaro

EDITORIAL SECRETARY
Edizioni Minerva Medica S.p.A.
Corso Bramante 83-85, 10126 Torino
T +39 011 678282
journals.dept@minervamedica.it

Designed by Biomedia srl
© 2025 SIBioC
P. IVA IT 06484860967